Series VB; with integrated overflow valve
3.6

Series VB with integrated overflow valve
Single systems with 950 min-1 and hp industrial pumps.
Suitable for use with hydraulic oils, lubricating oils, all fuel oils, coal and lignite tar oils, kerosene and many other self-lubricating fluids. The motor output data applies for fluids witha viscosity of up to 400 cSt. From 400 to 1000 cSt, the motor must be one power stage stronger. Available at a surcharge upon request.
The pump connections are indicated as follows:
A = suction connection
S = delivery connection
The standard model of the pumps is designed with a counterclockwise direction of rotation (viewed from the pump shaft). The position of the pump connections is independent of the direction of rotation. (See illustration.)
Direction of rotation l = counterclockwise, standard model
For clockwise rotation, D, the oil connections A = suction and S = delivery are interchanged
| Series size |
Pump type |
Discharge at 950 min -1 | Motor output |
Connections* | H1 Heater Watt |
Gear rotor/shaft |
Article-no. | ||
|---|---|---|---|---|---|---|---|---|---|
| at 0 - 9 bar | at 30 bar | ||||||||
| SMG 1841 | VBP | 30 l/h | – | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380027 | P max 9 bar |
| SMG 1842 | VBM | 55 l/h | – | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380028 | |
| SMG 1843 | VBG | 80 l/h | – | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380029 | |
| SMG 1844 | VBF | 105 l/h | – | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380030 | |
| SMG 1845 | VBGP | 200 l/h | – | 0,37 kW | G 1/2“ | 100 | 38/12 | 0380031 | |
| SMG 1846 | VBGM | 300 l/h | – | 0,37 kW | G 1/2“ | 100 | 38/12 | 0380032 | |
| SMG 1847 | VBGG | 400 l/h | – | 0,37 kW | G 1/2“ | 100 | 38/12 | 0380033 | |
| SMG 1848 | VBHP | 670 l/h | – | 0,75 kW | G 3/4“ | 160 | 56/18 | 0380034 | |
| SMG 1849 | VBHM | 1000 l/h | – | 0,75 kW | G 3/4“ | 160 | 56/18 | 0380035 | |
| SMG 1850 | VBHG | 1330 l/h | – | 1,1 kW | G 3/4“ | 160 | 56/18 | 0380036 | |
| SMG 1851 | VBHGP | 2000 l/h | – | 1,5 kW | G 1“ | 280 | 75/22 | 0380037 | |
| SMG 1852 | VBHGM | 3000 l/h | – | 2,2 kW | G 1“ | 280 | 75/22 | 0380038 | |
| SMG 1853 | VBHGG | 4000 l/h | – | 3,0 kW | G 1“ | 280 | 75/22 | 0380039 | |
| SMG 1861 | VBP | 30 l/h | 20 l/h | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380040 | P max 30 bar |
| SMG 1862 | VBM | 55 l/h | 40 l/h | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380041 | |
| SMG 1863 | VBG | 80 l/h | 60 l/h | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380042 | |
| SMG 1864 | VBF | 105 l/h | 90 l/h | 0,37 kW | G 3/8“ | 100 | 25/12 | 0380043 | |
| SMG 1865 | VBGP | 200 l/h | 160 l/h | 0,75 kW | G 1/2“ | 100 | 38/12 | 0380044 | |
| SMG 1866 | VBGM | 300 l/h | 260 l/h | 0,75 kW | G 1/2“ | 100 | 38/12 | 0380045 | |
| SMG 1867 | VBGG | 400 l/h | 360 l/h | 1,1 kW | G 1/2“ | 100 | 38/12 | 0380046 | |
| SMG 1868 | VBHP | 670 l/h | 470 l/h | 1,5 kW | G 3/4“ | 160 | 56/18 | 0380047 | |
| SMG 1869 | VBHM | 1000 l/h | 800 l/h | 2,2 kW | G 3/4“ | 160 | 56/18 | 0380048 | |
| SMG 1870 | VBHG | 1330 l/h | 1100 l/h | 3,0 kW | G 3/4“ | 160 | 56/18 | 0380049 | |
| SMG 1871 | VBHGP | 2000 l/h | 1400 l/h | 4,0 kW | G 1“ | 280 | 75/22 | 0380050 | |
| SMG 1872 | VBHGM | 3000 l/h | 2400 l/h | 5,5 kW | G 1“ | 280 | 75/22 | 0380051 | |
| SMG 1873 | VBHGG | 4000 l/h | 3200 l/h | 7,5 kW | G 1“ | 280 | 75/22 | 0380052 | |

Accessory
„WA” = oil pan and anti-vibration pads for mounting on the wall.
„LH” = oil leakage warning device has passed WHG and TÜV inspections.
Also suitable for alter installation on already installed aggregates to meet new regulations.
| Gear rotor/shaft |
Pan dimensions mm | Article-no. | ||
|---|---|---|---|---|
| L | B | H | ||
| 25/12 + 38/12 | 600 | 270 | 80 | 0820502 |
| 56/18 | 840 | 270 | 80 | 0820504 |
| 75/22 | 1050 | 360 | 80 | 0850065 |
| Fuel oil warning decide Type HMS at 230 V | 0720701 | |||
| Fuel oil warning decide Type HMW | 0720705 | |||

*To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site! The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.
| Size series |
Pump type |
Discharge | Motor output |
Dimensions | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| a | a1 | b | c | e1 | f3 | g | g1 | g2 | h | k | k1 | p | s | Pg | ||||
| SMG 1841 | VBP | 30 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1842 | VBM | 55 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1843 | VBG | 80 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1844 | VBF | 105 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1845 | VBGP | 200 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 1/2“ | 44 | 139 | 75 | – | 71 | 390 | 69 | 180 | 7 | 11 |
| SMG 1846 | VBGM | 300 l/h | 0,37 kW | 90 | 43 | 112 | 7 | G 1/2“ | 44 | 139 | 75 | – | 71 | 390 | 69 | 180 | 7 | 11 |
| SMG 1847 | VBGG | 400 l/h | 0,37 kW | 100 | 43 | 125 | 8 | G 1/2“ | 44 | 157 | 75 | – | 80 | 423 | 77 | 197 | 95 | 11 |
| SMG 1848 | VBHP | 670 l/h | 0,75 kW | 100 | 49 | 125 | 8 | G 3/4“ | 67 | 157 | 90 | – | 80 | 496 | 77 | 197 | 95 | 11 |
| SMG 1849 | VBHM | 1000 l/h | 0,75 kW | 100 | 49 | 140 | 13 | G 3/4“ | 67 | 181 | 90 | 137 | 80 | 531 | 92 | 214 | 11 | 135 |
| SMG 1850 | VBHG | 1330 l/h | 1,1 kW | 125 | 49 | 140 | 13 | G 3/4“ | 67 | 181 | 90 | 137 | 90 | 556 | 95 | 214 | 11 | 135 |
| SMG 1851 | VBHGP | 2000 l/h | 1,5 kW | 140 | 65 | 160 | 14 | G 1“ | 80 | 202 | 120 | 150 | 100 | 657 | 103 | 235 | 13 | 16 |
| SMG 1852 | VBHGM | 3000 l/h | 2,2 kW | 140 | 65 | 190 | 15 | G 1“ | 80 | 227 | 120 | 163 | 112 | 679 | 118 | 269 | 13 | 16 |
| SMG 1853 | VBHGG | 4000 l/h | 3,0 kW | 140 | 65 | 216 | 17 | G 1“ | 80 | 267 | 120 | 189 | 132 | 740 | 140 | 308 | 13 | 21 |
| SMG 1861 | VBP | 30 l/h 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 | |
| SMG 1862 | VBM | 55 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1863 | VBG | 80 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1864 | VBF | 105 l/h | 0,37 kW | 90 | 36 | 112 | 7 | G 3/8“ | 38 | 139 | 67 | – | 71 | 376 | 69 | 180 | 7 | 11 |
| SMG 1865 | VBGP | 200 l/h | 0,75 kW | 100 | 43 | 125 | 8 | G 1/2“ | 44 | 157 | 75 | – | 80 | 423 | 77 | 197 | 95 | 11 |
| SMG 1866 | VBGM | 300 l/h | 0,75 kW | 100 | 43 | 140 | 13 | G 1/2“ | 44 | 181 | 75 | 137 | 90 | 458 | 92 | 214 | 11 | 135 |
| SMG 1867 | VBGG | 400 l/h | 1,1 kW | 125 | 43 | 140 | 13 | G 1/2“ | 44 | 181 | 75 | 137 | 90 | 483 | 95 | 214 | 11 | 135 |
| SMG 1868 | VBHP | 670 l/h | 1,5 kW | 140 | 49 | 160 | 14 | G 3/4“ | 67 | 202 | 90 | 150 | 100 | 595 | 103 | 235 | 13 | 16 |
| SMG 1869 | VBHM | 1000 l/h | 2,2 kW | 140 | 49 | 190 | 15 | G 3/4“ | 67 | 227 | 90 | 163 | 112 | 617 | 118 | 269 | 13 | 16 |
| SMG 1870 | VBHG | 1330 l/h | 3,0 kW | 140 | 49 | 216 | 17 | G 3/4“ | 67 | 267 | 90 | 189 | 132 | 678 | 140 | 308 | 13 | 21 |
| SMG 1871 | VBHGP | 2000 l/h | 4,0 kW | 178 | 65 | 216 | 17 | G 1“ | 80 | 267 | 120 | 189 | 132 | 778 | 140 | 308 | 13 | 21 |
| SMG 1872 | VBHGM | 3000 l/h | 5,5 kW | 178 | 65 | 216 | 17 | G 1“ | 80 | 267 | 120 | 189 | 132 | 778 | 140 | 308 | 13 | 21 |
| SMG 1873 | VBHGG | 4000 l/h | kW | 210 | 65 | 254 | 20 | G 1“ | 80 | 324 | 120 | 209 | 160 | 877 | 157 | 366 | 16 | 21 |